What to do before starting the electronic ultrapure water equipment?
The electronic ultrapure water coagulation and sedimentation equipment is designed for different industries, different water requirements and different raw water, and is mainly used for the production of electronic products. This paper introduces what should be done before the electronic ultrapure water coagulation sedimentation equipment is started?
Preparations before starting the electronic ultrapure water coagulation sedimentation equipment are as follows:
1. The equipment is in good condition for standby;
2. The liquid level in the ultrafiltration tank is higher than 1/2;
3. The liquid level of intermediate water tank is higher than 1/3;
4. Online instrument is in good standby state;
5. The dosing equipment is in good condition, and the liquid level in the dosing tank is higher than 2/3;
6. Except the outlet valve and drain valve of reverse osmosis feed pump on the pipeline of pure water coagulation and sedimentation treatment equipment system, other valves can be opened flexibly;
What should we do before starting the electronic ultrapure water coagulation sedimentation equipment? 7. The reverse osmosis feed pump and high-pressure pump are in good standby state;
8. The safety filter is in standby state;
9. Check the main power supply, turn off the main power supply and instrument power supply on the main control panel, and set the reverse osmosis feed pump and high-pressure pump switches on the main control panel to the stop position.