13294301831         |

成功案例

当前位置:首页>成功案例

    Three Faults of Reverse Osmosis Purified Water Equipment and Their Solutions 

    发布时间:2022-11-19

    We all know that no matter what kind of machine, once it reaches its service life or is used for a long time, there will be some failures, which are difficult to avoid. In the same way, the reverse osmosis purified water coagulation sedimentation equipment will also have corresponding failures in the process of use. Generally speaking, the reverse osmosis purified water coagulation sedimentation equipment will have the following three failures. Then let's introduce it to you. How to deal with the three major failures and what solutions are available.

    1. Blockage of membrane

    The prefilter is not replaced or cleaned for a long time, which causes the water quality inside the machine to be far worse than that before entering the machine. The quality of raw water is poor, and the proportion of waste water is small, which causes the blockage of waste water solenoid valve or flushing combination valve, thus no waste water is produced, or very little waste water is produced, which leads to the blockage of membrane and the shorter service life of purified water equipment.

    2. Faulty transformer

    If the transformer is faulty and cannot provide the voltage required for normal pressurization of the pump, the speed will be slow, the increased pressure will be small, and the pressurization will be small. Naturally, the pressure required for tap water to pass through the RO membrane cannot be reached. At this time, the water production will be slow. According to the industry, it is necessary to replace a new transformer after removing the main factors affecting the slow water production, such as pump factors and membrane factors. Sometimes the check valve will also be blocked. Although this situation rarely occurs, we can take down the check valve to check the water yield during inspection. If there is a significant change in the water yield after and before removal, it means that the check valve is really blocked.

    Three major faults and solutions of reverse osmosis purified water coagulation sedimentation equipment 3. Filter element blockage

    One of the common faults of the purified water coagulation and sedimentation equipment is that the filter element is blocked. At present, the secondary pollution of tap water is becoming more and more serious. If we catch up to repair the pipeline again, the filter element can be said to be blocked. In industrial production, if there is no special person to maintain, the filter element will rarely be replaced, so the blockage is very common. It is very important to replace the filter element to prolong the service life of the equipment. Personnel shall be arranged for regular maintenance and replacement to ensure its smooth flow.

    The above is the introduction of the three major failures that the reverse osmosis purified water coagulation sedimentation equipment often encounters and the solutions. In fact, in addition to the three major failures, the reverse osmosis purified water equipment will encounter some other small problems in the process of use, but generally it is relatively easy to solve. I believe that these difficulties will not overwhelm the majority of users. I hope our solution can bring you some help.